• RM-9000
  • RM-9000
  • RM-9000
  • RM-9000
  • RM-9000
  • RM-9000
RM-9000
RM-9000
RM-9000
RM-9000
RM-9000
RM-9000
+

Share to

RM-9000

Detection radiation: X, γ and hard β rays. Detector: Energy compensated GM tube (Geiger counter) Measurement range dose equivalent rate: 0.01~100μSv/h Energy range: 48keV-1.5Mev≤±30% Sensitivity: 80CPM/μSv (for Co-60) Relative inherent error: ±15% Operating environment: Temperature: -10~45℃, Humidity: ≤95%RH Dimensions: 70x135x24mm Net weight: 101g Gross weight: 166g With aircraft box: 226g

Still hesitating? Get a sample first, contact us!

Keyword:

Microcrystalline glass electric heating

  • Product Description

RM-9000

CE
Detection radiation: X, γ and hard β rays. Detector: Energy compensated GM tube (Geiger counter) Measurement range dose equivalent rate: 0.01~100μSv/h Energy range: 48keV-1.5Mev≤±30% Sensitivity: 80CPM/μSv (for Co-60) Relative inherent error: ±15% Operating environment: Temperature: -10~45℃, Humidity: ≤95%RH Dimensions: 70x135x24mm Net weight: 101g Gross weight: 166g With aircraft box: 226g
+
  • RM-9000- (1).png
  • RM-9000- (7).png
  • RM-9000- (2).png
  • RM-9000- (3).png
  • RM-9000- (6).png
  • RM-9000- (8).png

RM-9000

Detection radiation: X, γ and hard β rays. Detector: Energy compensated GM tube (Geiger counter) Measurement range dose equivalent rate: 0.01~100μSv/h Energy range: 48keV-1.5Mev≤±30% Sensitivity: 80CPM/μSv (for Co-60) Relative inherent error: ±15% Operating environment: Temperature: -10~45℃, Humidity: ≤95%RH Dimensions: 70x135x24mm Net weight: 101g Gross weight: 166g With aircraft box: 226g



Keyword:


Product Details


Contact Us


We are committed to providing customers with high-quality products and services

Image Name

Rita

Marketing Center

Image Name

Sofia

Image Name

Alma

Image Name

Shirley

Image Name

Tiffany

Image Name

Lucy

We are committed to providing customers with high-quality products and services

Submit Form
%{tishi_zhanwei}%

Related Products

Sensor: Semiconductor sensor Size: 34 x 120 x 19.1mm Material: ABS Power supply: 2 x AAA batteries Measurement range: 0 - 0.95mg/L Heating time: 10 seconds Blowing time: 10 seconds Net weight: 42.5g Weight: 80g

Detection radiation: X-rays, γ-rays and β-rays. Detector: Geiger counter Current dose rate measurement range: 0~10000μSv/h (10mSv/h) Cumulative dose equivalent range: 0~500mSv Energy range: 50keV-3Mev≤±30% Relative inherent error: ±15% Sensitivity: 60CPM/μSv Dimensions: 55x112x19.6mm Battery capacity: 800mAh Power supply: USB Type-C 5V=1A Net weight: 73g Gross weight: 202g